Banca de DEFESA: Fernanda Ferreira Caldas

Uma banca de DEFESA de DOUTORADO foi cadastrada pelo programa.
STUDENT : Fernanda Ferreira Caldas
DATE: 26/11/2022
TIME: 10:00
LOCAL: Auditório nº 2 da FS/UnB
TITLE:

“A novel cochlear implant assessment tool: audiometric and speech recognition analysis”

 

KEY WORDS:

“cochlear implant, speech recognition, noise, auditory thresholds”.

 

PAGES: 100
BIG AREA: Ciências da Saúde
AREA: Fonoaudiologia
SUMMARY:

“Introduction: To evaluate the results with the cochlear implant (CI), it is necessary to evaluate the thresholds with pure tone audiometry (PTA) and the speech recognition tests in silence and noise. The sound booth (SB) is the traditional tool for these evaluations, however, the Direct Audio Input - DAI, can also evaluate the hearing capacity and the performance of users with CI, in this way, the company Cochlear Corporation launched the Cochlear Latin America Box (CLABOX), to be used with the DAI connection. Objective: To compare the evaluations between the CLABOX and the SB in PTA and in the speech recognition test. Material and Method: The study included 33 adults and 17 children, aged from 8 years old, 15 bilateral CI users and 35 unilateral CI users, all with severe to profound bilateral sensorineural hearing loss. All participants underwent evaluations in the SB, with free field, and in the CLABOX, with DAI connection. Assessments performed: PTA, speech perception tests, with the Hearing in Noise Test (HINT), Ling sounds and visual analogue scale (VAS). Results: In HINT with adaptive noise, the results were significant (p value = 0.007); the S/R ratio was +2.14dB in the CLABOX and +3.42dB in the SB. For the four-tone mean, the mean thresholds for CLABOX and SB were 29.8dB and 23dB, respectively (p-values < 0.001). The VAS results were higher in the CLABOX, but there was no significant difference compared to the SB. In the group of children and adults, the results were not statistically significant in the evaluations of the tests with the PTA and speech recognition test in noise (HINT), in the CLABOX and in the SB. Conclusion: The CLABOX with DAI connection proved to be a tool with the possibility to evaluate the PTA e and speech recognition tests, when compared to the conventional evaluation, in a sound booth, of the same individual and between children and adults. The subjective evaluation with the VAS was effective for the comparison and equality between the two evaluated tools”.


BANKING MEMBERS:
Externo à Instituição - CARLOS AUGUSTO COSTA PIRES DE OLIVEIRA - HUB
Presidente - 783.299.221-20 - FAYEZ BAHMAD JUNIOR - NÃO INFORMADO
Externa ao Programa - 2142935 - ISABELLA MONTEIRO DE CASTRO SILVA
Externo à Instituição - MARIA VALÉRIA SCHMIDT GOFFI GOMEZ - USP
Externa à Instituição - RENATA DE SOUSA TSCHIEDEL - SESDF
Notícia cadastrada em: 21/11/2022 11:26
SIGAA | Secretaria de Tecnologia da Informação - STI - (61) 3107-0102 | Copyright © 2006-2024 - UFRN - app14_Prod.sigaa08